Produktdetails:
Herkunftsort: China
Modellnummer: PH-281A
Zahlung und Versand AGB:
Min Bestellmenge: 1 Stück PH-281A wasserdichter Stift PH-Messgeräte PH-Tester
Preis: USD1 of PH-281A waterproof pen PH meters PH testers
Verpackung Informationen: 100 Stück / Karton PH-281A wasserdichter Stift PH-Messgeräte PH-Tester
Lieferzeit: 10 Tage PH-281A wasserdichter Stift PH-Messgeräte PH-Tester
Zahlungsbedingungen: TT von PH-281A wasserdichter Stift PH-Messgeräte PH-Tester
Versorgungsmaterial-Fähigkeit: 5000000 Stück PH-281A wasserdichter Stift PH-Messgeräte PH-Tester
Kontakt
Ausführliche Produkt-Beschreibung

PH-281A waterproof pen PH meters PH testers

Specification:

Range:0.0-14.0pH     Resolution:0.01pH

Accuracy:±0.05pH or 0.1pH    Power:4*1.5V

Calibration:1 point  Dimension: 172*26*26mm

ATC:0-60℃

N.W:93g    G.W: 145g

Package: 100pcs/carton, 15kg/carton

 

OPERATION

• Remove the protective cap. Do not be alarmed if white crystals appear around the cap. This is normal with pH electrodes and they dissolve when rinsed with water.

• Turn the meter on by pressing on/off key.

• Immerse into solution up to the max immersion level.

• Stir gently and wait until the display stabilizes.

• After use, switch off pH meter, use the water clean the electrode and replace the protective cap.

• Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.

 

 

CALIBRATION

• Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution

• Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.86

Calibration is now complete.

ALWAYS USE FRESH BUFFERS FOR CALIBRATION.

 

BATTERY REPLACEMENT

When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.

 

WARRANTY

These instruments are warranted from all defects in material and manufacturing for a period of one year from the date of purchase.

If during this period, the repair or the replacement of parts is required where the damage is not due to negligence or erroneous operation by user, please return the parts to either dealer or our offices, and the repair will be effected free of charge.

Kontaktdaten
Please input your companyname!
Senden Sie Ihre Anfrage direkt an uns (0 / 3000)

Andere Produkte
Referenzen

| Sitemap

Datenschutz-Bestimmungen | China Pen PH meter, ORP meter, TDS meter, Conductivity meter Fournisseur. Copyright © 2026 Please input your companyname!. All Rights Reserved. Developed by ECER